Winter Solar Survival Simulator: Can Your Off-Grid Battery Cover Cloudy Days?

Explore how changing solar panels, battery storage, hourly appliance use and discharge power limits affects unmet electricity needs through a modeled winter period. Unlike a simple daily-energy sizing rule, this tool tracks the battery from one hour to the next.

Educational planning estimate, not a forecast or a survival guarantee. Sunlight patterns here are synthetic, not actual observations for your location. An apparently adequate hourly model does not certify inverter startup, battery charging in freezing conditions, motor operation, code compliance or backup reliability.

Illustrative hourly simulation

Try a cloudy-weather battery scenario

Compare a cabin, van or always-on network system through three synthetic sunlight patterns. Everything runs in your browser. This is not site-specific weather or certified equipment operation.

1. Start with a system

Daily appliance Wh comes from the Off-Grid Builder. Uniform hourly timing is assumed until you edit and confirm it.

2. Weather challenge

All weather is synthetic, not observed, forecast or geolocated. The seven-day pattern repeats at 14 days.

3. Solar and storage

Builder-sized storage is an editable illustration, not an installed battery. Initial 100% SoC is an optimistic starting assumption.

4. Efficiency and power ceilings

Blank means not verified, never a certified unlimited rating. Battery/solar power ratings are DC-bus W; inverter/converter outputs are device-side W.

Advanced: edit appliance priority and 24-hour assumptions

Every active appliance receives 24 daily energy weights (sum 1) and 24 hourly availability fractions (sum equals builder-required availability hours, if declared). Separate numbers with commas. No demand is moved between hours after a shortfall.

Confirm assumed schedules to enable a simulation.

Keep, transfer or share this winter scenario

Saved scenarios stay in this browser. JSON and share fragments contain equipment and load assumptions; inspect before sharing. Never put confidential site details in a share URL.

Hand-checked example

Why a battery can fall short before it runs out of stored energy

Consider a hypothetical system with a 4,000 Wh nominal battery, a 25% minimum state of charge, 2,000 Wh initial stored energy, 80% charging and discharging efficiency, and a 500 W battery charging and discharge limit measured at the DC bus. A divisible, directly supplied DC load requests different amounts in four consecutive one-hour periods. PV energy is listed after the controller, so its values are ready to enter the DC-bus balance.

Independent four-hour energy-ledger example (Wh)
HourPV to DC busUser requestUser servedUnmetPV curtailedStored at end
12,00040040001,1002,400
2080050030001,775
3080050030001,150
4040012028001,000

Result: the load receives 1,520 Wh, misses 880 Wh, and finishes with 1,000 Wh stored (the configured 25% reserve floor). It curtails 1,100 Wh of solar in the first hour. The first hour with unmet modeled demand is hour 2, when the 500 W discharge power ceiling limits service to 500 Wh even though more energy remains in storage. Hour 4 is limited by the minimum battery SoC.

Energy check: 2,000 Wh initial battery + 2,000 Wh PV = 1,520 Wh served + 1,100 Wh curtailed + 100 Wh charge loss + 280 Wh discharge loss + 1,000 Wh final battery = 4,000 Wh.

This is an independent, deliberately simple test fixture, not the entire preset weather scenario above. It checks conservation and the chronological battery state, and it makes the distinction between energy (Wh) and power (W) visible.

How the hourly model works

1. Demand by appliance

Each appliance keeps its validated daily delivered Wh from the Off-Grid System Builder. You can inspect and edit 24 allocation weights, the availability fractions, and critical versus noncritical priorities. Without your measured readings, the hourly usage distribution is assumed.

2. PV at the DC bus

Solar generation follows a bundled, normalized synthetic daylight shape. The model separately accounts for declared controller efficiency, extra non-overlapping loss assumptions and controller bus-output limitations. It does not reuse the Builder's daily peak-sun-hours multiplier.

3. Storage, reserve and power

Stored battery energy evolves from hour to hour between nameplate capacity and its minimum SoC reserve. Charging and discharging losses are applied to energy crossing the battery boundary; limits are in DC-bus W. Unknown equipment limits are explicitly unverified.

4. Priority and curtailed energy

Loads are served in deterministic critical-first order; an atomic hour-equivalent load is either fully served or not served, while a divisible load may receive only mathematical partial energy. Inverter idle is reserved once as a prerequisite for AC operation; inadequate energy for idle triggers modeled inverter shutdown, not a fictional partially running inverter.

Three illustrative options—clearer cold days, prolonged overcast, and two particularly poor-sun days—are offered at 3, 7 and 14 days. The 24-hour appliance pattern repeats daily and the synthetic seven-day solar pattern repeats in the 14-day exercise. These are not local historical irradiance, probability estimates, sunrise calculations, generator scheduling or a substitute for equipment manuals.

Questions to consider before relying on an off-grid design

Does “no modeled shortfall” mean my cabin will have uninterrupted electricity?

No. It means this particular synthetic hourly energy calculation served all requested Wh. Sub-hour load peaks, surge current, actual winter solar conditions, ambient-versus-cell temperature, snow, shading and real equipment interactions were not established.

Why can my battery be above its minimum SoC when a load goes unserved?

Wh measures energy remaining, whereas watts limit the rate of delivery. A discharge-power cap, a known inverter rating conflict, converter limits, appliance priority or inverter shutdown may cause unmet demand while stored energy remains.

Can I trust a storage size imported from the Off-Grid Builder?

The transferred battery is the Builder's illustrative sized capacity, not confirmed hardware. The model takes its nominal Wh unchanged and uses the Builder's usable fraction only to derive the reserve floor. Verify actual equipment capacity, charge specifications and battery management behavior separately.

Is the simulation using actual weather for my town?

No. v1 has no city data, real-time forecast, historical weather record or geolocation. A separately sourced and validated location-based dataset would be a future feature. For now, use the outcomes only to explore relative sensitivity to assumptions.